Tel: +86-755-28408621
E-mail: [email protected]
Description
JKDC-5030A is primarily used in garment and shoe industries to detect metal contamination in packets or products. With X-ray scanner detecting. More strong penetration.Which show object interior metal structure by LCD screen. Especially designed for tourist spot, gymnasium, conference centre, exhibition, baggage deposit, shopping mall, hotel and other important locations; Different situation with different options, Efficiency, Excellence performance VS preferential Price, Easy for Carring, Removable; Strict quality control, double test in engineering and producing, spare parts guaranteed; high performance network:Customers optional training mode:Test report from Inspection Center of State Public Security Ministry; Radiation safety certificate from China Government, ISO9001 Certification.
Feature
X-ray Generator
Generate direct: Upward
Generate angle: 60 degree
Anode Voltage: 80Kv
Anode power: 0.4 to 0.5 mA
Cooling / Duty Cycle: Oil Cooling /100%
5030A penetration: 14 mm
Image System
X-ray Sensor: L-Shaped Photodiode Array (monoenergetic), 16 bit Deep
Monitor: High Resolution Color, LCD Accord, 19 inches
Image Processing: Edge enhancement, image strengthening, image lightening, reducing darkening, image returning, image retrieval.
Image Grey Level: 4096
Image Max Resolution: 1024 * 1280 pixel
Image Processing: 24bit for processing real time
Image storage: Storage 10,000 pictures in real time
Specifications
Tunnel Size | 500(W)×300(H)mm |
Conveyor Speed | 0.2m/s |
Conveyor Max Load | 100kg |
Dose per Inspection | less than 1.5 μGy/h |
Wire Resolution | 32AWGΦ0.202mm |
Spatial Resolution | Level: dia1.0mm, Vertical: dia1.3mm |
Penetration | 14mm Stell |
Film Safety | Guarantee ISO1600 Film |
X ray Leakage |
less than 1 μGy/h (at a distance of 5cm from frame house) |
Monitor | 19inch |
Operation temperature/Humidity | 0°C-45°C/20%-95%(non-condensing) |
Storage Temperature/Humidity | -20°C-60°C/20%-95%(non-condensing ) |
Operation Power | 220VAC(±10%)50±3Hz |
Power Consumption |
less than 0.5KW |
The real performance of the X-ray Machine: